personal care: Hanna Instruments ...
personal care:
Air temperature K-type thermocouple probe with stainless steel tube (model #HI 766PD)
Hanna Instruments
Hanna Instruments
These Probes are all specially constructed for excellent contact with the surface being measured. The several different options below are designed to meet all of your surface temperature measurement needs. Due to the high surface temperature
Hanna Instruments-Conductivity Probes
Hanna Instruments
Hanna Instruments
Hanna Instruments was the first instrumentation manufacturer to offer a 4-ring potentiometric probe with a conductivity meter. The potentiometric method of measuring electrical conductivity in liquids is by far the most accurate method available today. The four rings are aligned concentrically on the probe shaft. The two outer rings apply a voltage which creates a buffer field around the two inner rings. The inner rings pick up a current and ...
Hanna Instruments-HI 766 K-Type Thermocouple Probes
Hanna Instruments
Hanna Instruments
Due to Hi surface temps involved, is important that probe handle does not reach a temp above 302°F (150°C). If this happens, probe may be damaged. Response times all refer to 63.2% of measuring range. HI 766 K-Type Thermocouple Probes w/integral handle, 3.3'(1M) cable & mini-connector. HI766A: Roller surface probe 600°F(320°C) 11"x4" (280mmx100mm) . HI766B: Surface temp. probe 1200°F (650°C) 11"x0.6" (280mmx16mm). HI 766C: Penetration Probe ...
Hanna Instruments-HI 180 Popular Magnetic Mini-Stirrers: Small
Hanna Instruments
Hanna Instruments
9 colors available:HI 180 A Light yellow-HI 180 B Light sea-green-HI 180 C Light blue-HI 180 D Yellow-HI 180 E Green-HI 180 F Dark blue-HI 180 G Red-HI 180 H Grey-HI 180 I Ivory. The new Hanna HI 180 series are compact, lightweight, low-cost and designed in a special round shape without any sharp corners. Lack of laboratory bench space is no longer a concern. Available in nine colors, light yellow, light sea-green, light blue, yellow, green, ...
Hanna Instruments-HI 991404 & HI 991405 - pH, EC, TDS, Temperature Monitors
Hanna Instruments
Hanna Instruments
Measures from 0 to 3999 µS/cm and 0.00 to 20.00 mS/cm. Simple one-point calibration. Automatic temperature compensation. The new Combo HI 991404 & HI 991405 series meters from Hanna are designed for continuous, high accuracy pH, EC/TDS and temperature measurements. These microprocessor indicators continuously monitor the three most important nutrient parameters in hydroponics, greenhouses and horticultural applications with a single instrument. ...
Checker®1pH tester (model #HI 98103)
Hanna Instruments
Hanna Instruments
High accuracy with 0.01 pH resolution Usable with virtually any pH electrode Battery life: 3000 hours of continuous use
Hanna Instruments-HI 768 Pt100 Four Wire Probes
Hanna Instruments
Hanna Instruments
HI 768P General Purpose Penetration Probe. HI 768P: 3.3' (1 m). HI 768A Air/Gas Probe. HI 768A: 3.3' (1 m). HI 768L General Purpose/Liquid Probe. HI 768L: 3.3' (1 m). HI 768L/3: 10' (3 m). HI 768L/5: 16.5' (5 m).
Hanna Instruments-HI 768 Pt100 Four Wire Probes
Hanna Instruments
Hanna Instruments
HI 768P General Purpose Penetration Probe. HI 768P: 3.3' (1 m). HI 768A Air/Gas Probe. HI 768A: 3.3' (1 m). HI 768L General Purpose/Liquid Probe. HI 768L: 3.3' (1 m). HI 768L/3: 10' (3 m). HI 768L/5: 16.5' (5 m).
Hanna Instruments-Thermistor Probes & Sensors
Hanna Instruments
Hanna Instruments
Rnge: -58to302°F(-50to150°C). Accuracy: ±0.4°F(±0.2°C). Interchange Error: ±0.4°F(±0.2°C). T.C.: 15Sec. Sensor According to: Mil std T-23648. Probe Hndl: ABS. Probe: SS AISI 316 / 3.9 " x 0.12"(100mmx3mm). Max Error: Probes supplied w/max error of ±0.4°F(±0.2°C). The HI762 series supplied w/grey cap for ID purposes. HI762P Gen Purpose Pen Probe w/Colored HndlHI762PW: 3.3'(1m)Wht Hndl. HI762PW/10: 33'(10m)Wht Hndl. HI762PBL: 3.3'(1m)Blu Hndl. ...
Hanna Instruments-Ammonia Colorimeters
Hanna Instruments
Hanna Instruments
Ammonia is often an excellent indication of the presence of animal or plant microbiological decay. It is tested in fish farms (fresh and salt water tanks) due to the damaging effects of its toxic nature. Its presence in rivers and reservoirs normally points to agricultural and/or civil pollutants. Ammonia is tested in lakes, rivers, potable water, boiler feed water, sewage, industrial and waste water. Ion Selective electrodes currently used for ...
search in the category 'health & personal care'
766pd
,
98103
,
991404
,
991405
,
ammonia
,
checker
,
colorimeters
,
conductivity
,
hanna
,
instruments
,
instruments-ammonia
,
instruments-conductivity
,
instruments-hi
,
instruments-thermistor
,
k-type
,
magnetic
,
mini-stirrers
,
monitors
,
popular
,
probe
,
probes
,
pt100
,
sensors
,
small
,
stainless
,
stirrers
,
temperature
,
tester
,
thermistor
,
thermocouple
personal care:
Kindle - Amazon's New Wireless Reading Device
This is the future of book reading. I have used it and love it!
randomly chosen
VHS:
Lady Boss
home
impressum - about us